In the context of international economic integration and efforts toward sustainable development, compliance with energy efficiency regulations is becoming increasingly urgent, creating both challenges and new opportunities for enterprises manufacturing, importing, and trading electronic equipment. In particular, clearly understanding the List of products subject to Mandatory Energy Labeling is a key factor, directly affecting production, import, and business activities in Vietnam.
See more: Capacity Profile Of Phuc Gia Laboratory Corporation

Based on:
- Decision 04/2017/QĐ-TTG – Prescribing the List of Vehicles and Equipment Subject to Mandatory Energy Labeling, Application of Minimum Energy Efficiency Levels, and Implementation Roadmap
- Circular 36/2016/TT-BCT – Regulating Energy Labeling for Energy-Using Vehicles and Equipment Under the Management Scope of the Ministry of Industry and Trade
- Decision No. 14/2023/QĐ-TTg – regarding the List and roadmap of energy-using vehicles and equipment to be discarded and low-efficiency power generating units not allowed for new construction, issued by the Prime Minister to replace Decision 24/2018/QĐ-TTg
| ORD | ARTICLE NAME | ARTICLE LINK |
| I. Household Equipment Group: | ||
| 1 | Compact fluorescent lamps TCVN 7896:2015
– This standard applies to compact fluorescent lamps (hereinafter abbreviated as CFL) operating with integrated electronic ballasts, with a power range from 5 W to 60 W, used for general lighting purposes. |
https://phucgia.com.vn/dan-nhan-nang-luong-den-huynh-quang-ong-thang
|
| 2 | Electronic ballasts for fluorescent lamps TCVN 7897:2013
– This standard specifies energy efficiency requirements for electronic ballasts used with alternating current power sources, voltage up to 1000 V, frequency 50 Hz or 60 Hz, used for fluorescent lamp(s) with power from 4 W to 65 W. |
https://phucgia.com.vn/cong-bo-dan-nhan-nang-luong-ba-lat-sat-tu-dien-tu |
| 3 | Electromagnetic ballasts for fluorescent lamps TCVN 8248:2013
– This standard specifies energy efficiency requirements for electromagnetic ballasts, excluding the resistor type, for use with alternating current power sources, voltage up to 1000 V, frequency 50 Hz or 60 Hz, used for fluorescent lamps with power from 4 W to 65 W. |
https://phucgia.com.vn/cong-bo-dan-nhan-nang-luong-ba-lat-sat-tu-dien-tu |
| 4 | Double-capped fluorescent lamps (linear) TCVN 8249:2013
– This standard applies to double-capped linear fluorescent lamps used for general lighting purposes (hereinafter referred to as fluorescent lamps), with a power range from 4 W to 65 W, used with both 50 Hz ballasts and high-frequency ballasts connected to a power grid with a nominal voltage of 220 V. |
https://phucgia.com.vn/dan-nhan-nang-luong-den-huynh-quang-ong-thang
|
| 5 | LED lamps TCVN 11844:2017
– This standard specifies energy efficiency levels for self-ballasted LED lamps with E27 and B22 caps and double-capped LED lamps designed to replace linear fluorescent lamps with G5 and G13 caps, used for general purposes, with power up to 60 W, and nominal voltage not exceeding 250 V. |
https://phucgia.com.vn/cong-bo-dan-nhan-nang-luong-den-led-nhanh |
| 6 | Electric fans TCVN 7826:2015:
– Desk fans, – Floor fans, – Wall fans, – Window fans, – Ceiling fans, – Roof fans, with integrated electric motors having a power not exceeding 125 W. |
https://phucgia.com.vn/dan-nhan-nang-luong-quat-dien |
| 7 | Refrigerators, freezers TCVN 7828:2016:
– This standard applies to wine chillers, refrigerators, and freezers with a capacity up to 1,000 L, cooled by natural convection or forced air circulation. |
https://phucgia.com.vn/dan-nhan-nang-luong-tu-lanh |
| 8 | Ductless air conditioners TCVN 7830:2015:
– Ceiling-mounted air conditioners, – Wall-mounted air conditioners, – Ducted air conditioners (nominal cooling capacity less than 8000 W). |
https://phucgia.com.vn/dan-nhan-nang-luong-dieu-hoa |
| 9 | Household washing machines TCVN 8526:2013
– This standard specifies energy efficiency levels and methods for determining energy efficiency for household clothes washing machines, with or without heating devices using cold and/or hot water sources, with a nominal capacity from 2 kg to 15 kg, using a 220 V AC power source, 50 Hz frequency. |
https://phucgia.com.vn/dan-nhan-nang-luong-may-giat |
| 10 | Television receivers TCVN 9536:2012
– This standard applies to television receivers with a nominal power of less than 1000 W, consisting of a tuner/receiver and a display screen within the same enclosure. Designed to receive and display broadcast television signals via antenna, satellite, or cable. – This standard applies to combined TV/VCR, TV/DVD, and TV/VCR/DVD units. |
https://phucgia.com.vn/dan-nhan-nang-luong-tivi |
| 11 | Electric rice cookers TCVN 8252:2015
– This standard applies to general-purpose electric rice cookers used in households and similar purposes, with a nominal power up to 2000 W. – This standard applies to electric rice cookers using resistance heating methods, induction heating, or induction, operating at normal atmospheric pressure. |
https://phucgia.com.vn/dan-nhan-nang-luong-noi-com-dien |
| 12 | Storage water heaters TCVN 7898:2018
– This standard applies to electric storage water heaters (hereinafter referred to as water heaters) used in households and similar purposes with a capacity up to 50 liters. |
https://phucgia.com.vn/dan-nhan-nang-luong-binh-nuoc-nong-du-tru |
| II. Commercial and Office Equipment Group: | ||
| 1 | Computer monitors TCVN 9508:2012
– This standard applies to computer monitors (hereinafter referred to as monitors) comprising a display screen and associated electronic circuitry, usually assembled in a single enclosure, capable of displaying visual information from a computer via one or more inputs, such as VGA and DVI. |
https://phucgia.com.vn/dan-nhan-nang-luong-man-hinh-may-tinh |
| 2 | Laptops TCVN 11848:2017
– Laptops within the scope of this standard are computers defined in section 4.1.2. |
https://phucgia.com.vn/cong-bo-dan-nhan-nang-luong-may-tinh-xach-tay-nhanh |
| 3 | Printers TCVN 9509:2012
– This standard applies to standard format printers; – This standard applies to equipment performing multiple functions of photocopiers, fax machines, and scanners; |
https://phucgia.com.vn/dan-nhan-nang-luong-may-in |
| 4 | Photocopiers TCVN 9510:2012
– This standard applies to standard format photocopiers whose main function is to produce multiple hard copies identical to the original. – This standard applies to equipment performing multiple functions such as the functions of printers, fax machines, and scanners. |
https://phucgia.com.vn/cong-bo-dan-nhan-nang-luong-may-photocopy-nhanh |
| 5 | Commercial refrigerated cabinets TCVN 10289:2014
– Commercial refrigerated cabinets used for the sale and display of food. |
https://phucgia.com.vn/dan-nhan-nang-luong-tu-mat |
| III. Industrial Equipment Group: | ||
| 1 |
Electric motors TCVN 7540-1:2013 Single-speed, three-phase, squirrel-cage induction motors using 50 Hz and/or 60 Hz frequency power sources and: – Having a nominal voltage UN up to 1000 V; – Having a nominal output power PN from 0.75 kW to 150 kW; – Having 2, 4, or 6 poles; – Operating in S1 duty cycle (continuous duty); – Operating directly on the grid; Motors equipped with detachable gearboxes or braking mechanisms are also within the scope of this standard, even though special shafts and flanges may be used in these motors. |
https://phucgia.com.vn/dan-nhan-nang-luong-dong-co-dien |
| 2 | Transformers TCVN 8525:2010:
– 3-phase distribution transformers (oil-immersed). |
https://phucgia.com.vn/dan-nhan-nang-luong-may-bien-ap |
| 3 | Boilers TCVN 8630:2010:
– Types of boilers currently in use, for which the mass and calorific value of the fuel used can be determined. |
https://phucgia.com.vn/hieu-suat-nang-luong-lo-hoi |
For more details, please contact us at:
PHUC GIA LABORATORY CORPORATION
PHUC GIA CERTIFICATION CENTER
PHUC GIA INSPECTION TESTING CENTER
Address:
- Hanoi: ICD Long Bien, No. 01 Huynh Tan Phat, Sai Dong B Industrial Park, Long Bien Ward
- Ho Chi Minh City: No. 180, D2 Street, Long Truong Ward
Hotline: 0965996696 / 0982996696 / 02477796696
E-mail: lab@phucgia.com.vn/cert@phucgia.com.vn/info@phucgia.com.vn
Website: phucgia.com.vn
Working time: Monday to Friday 8:00 – 18:30; Saturday 8:00 – 12:00